XC TYPE RECTANGULAR CONNECTOR

XC TYPE RECTANGULAR CONNECTOR

The socket on the tab side is designed to enable 2 branches for 2 circuits with 4 terminals, 2 branches for 10 circuits with 20 terminals, and 4 branches for 10 circuits with 40 terminals. A variation with screw terminals for 10 poles is available for leading in external wiring.

The plug on the receptacle side is available in the hook movable types for 2 and 10 poles, the hook locked types for 1 and 10 poles, and the screw terminal type for 10 poles for use in leading in external wiring.

The socket and plug can be quickly mounted to the switchboard by pressing them.

The use of this connector allows for standardizing wiring and complying with the wire harness system (combined electric wire system) that enable pre-work by dividing the wiring work.

FEATURES

  Rated insulation voltage (Ui) Rated current-carrying capacity (Ith) Max. wire size Withstand voltage Lightning impulse Short-time current Contact resistance Shock resistance Operating temperature Storing temperature Relative humidity Altitude
XC-P1 600V 10A 0.3mm2 to 2.27mm2 (The XC-T10 screw terminal is of 5.5mm2 maximum.) (Between live parts and mounting panel) ±7,000 V/3 times for each pole (1.2/50μs) (Between live parts) ±4,500 V/3 times for each pole (1.2/50μs) (Between live parts and mounting panel) ±7kV/3 times for each pole (1.2/50μs) (Between live parts) ±4.5kV/3 times for each pole (1.2/50μs) 100A 2 seconds Between poles 10mΩ max. (initial value) 50G or more/each axial direction -20 to 50℃ -40 to 85℃ 85% max. 2,000m max.
XC-P2M 600V 10A 0.3mm2 to 2.27mm2 (The XC-T10 screw terminal is of 5.5mm2 maximum.) (Between live parts and mounting panel) ±7,000 V/3 times for each pole (1.2/50μs) (Between live parts) ±4,500 V/3 times for each pole (1.2/50μs) (Between live parts and mounting panel) ±7kV/3 times for each pole (1.2/50μs) (Between live parts) ±4.5kV/3 times for each pole (1.2/50μs) 100A 2 seconds Between poles 10mΩ max. (initial value) 50G or more/each axial direction -20 to 50℃ -40 to 85℃ 85% max. 2,000m max.
XC-P10T 600V 10A 0.3mm2 to 2.27mm2 (The XC-T10 screw terminal is of 5.5mm2 maximum.) (Between live parts and mounting panel) ±7,000 V/3 times for each pole (1.2/50μs) (Between live parts) ±4,500 V/3 times for each pole (1.2/50μs) (Between live parts and mounting panel) ±7kV/3 times for each pole (1.2/50μs) (Between live parts) ±4.5kV/3 times for each pole (1.2/50μs) 100A 2 seconds Between poles 10mΩ max. (initial value) 50G or more/each axial direction -20 to 50℃ -40 to 85℃ 85% max. 2,000m max.
XC-P10M 600V 10A 0.3mm2 to 2.27mm2 (The XC-T10 screw terminal is of 5.5mm2 maximum.) (Between live parts and mounting panel) ±7,000 V/3 times for each pole (1.2/50μs) (Between live parts) ±4,500 V/3 times for each pole (1.2/50μs) (Between live parts and mounting panel) ±7kV/3 times for each pole (1.2/50μs) (Between live parts) ±4.5kV/3 times for each pole (1.2/50μs) 100A 2 seconds Between poles 10mΩ max. (initial value) 50G or more/each axial direction -20 to 50℃ -40 to 85℃ 85% max. 2,000m max.
XC-T10 600V 10A 0.3mm2 to 2.27mm2 (The XC-T10 screw terminal is of 5.5mm2 maximum.) (Between live parts and mounting panel) ±7,000 V/3 times for each pole (1.2/50μs) (Between live parts) ±4,500 V/3 times for each pole (1.2/50μs) (Between live parts and mounting panel) ±7kV/3 times for each pole (1.2/50μs) (Between live parts) ±4.5kV/3 times for each pole (1.2/50μs) 100A 2 seconds Between poles 10mΩ max. (initial value) 50G or more/each axial direction -20 to 50℃ -40 to 85℃ 85% max. 2,000m max.
XC-S4 600V 10A 0.3mm2 to 2.27mm2 (The XC-T10 screw terminal is of 5.5mm2 maximum.) (Between live parts and mounting panel) ±7,000 V/3 times for each pole (1.2/50μs) (Between live parts) ±4,500 V/3 times for each pole (1.2/50μs) (Between live parts and mounting panel) ±7kV/3 times for each pole (1.2/50μs) (Between live parts) ±4.5kV/3 times for each pole (1.2/50μs) 100A 2 seconds Between poles 10mΩ max. (initial value) 50G or more/each axial direction -20 to 50℃ -40 to 85℃ 85% max. 2,000m max.
XC-S20 600V 10A 0.3mm2 to 2.27mm2 (The XC-T10 screw terminal is of 5.5mm2 maximum.) (Between live parts and mounting panel) ±7,000 V/3 times for each pole (1.2/50μs) (Between live parts) ±4,500 V/3 times for each pole (1.2/50μs) (Between live parts and mounting panel) ±7kV/3 times for each pole (1.2/50μs) (Between live parts) ±4.5kV/3 times for each pole (1.2/50μs) 100A 2 seconds Between poles 10mΩ max. (initial value) 50G or more/each axial direction -20 to 50℃ -40 to 85℃ 85% max. 2,000m max.
XC-S40 600V 10A 0.3mm2 to 2.27mm2 (The XC-T10 screw terminal is of 5.5mm2 maximum.) (Between live parts and mounting panel) ±7,000 V/3 times for each pole (1.2/50μs) (Between live parts) ±4,500 V/3 times for each pole (1.2/50μs) (Between live parts and mounting panel) ±7kV/3 times for each pole (1.2/50μs) (Between live parts) ±4.5kV/3 times for each pole (1.2/50μs) 100A 2 seconds Between poles 10mΩ max. (initial value) 50G or more/each axial direction -20 to 50℃ -40 to 85℃ 85% max. 2,000m max.
product document data type volume of data date of update download
XC TYPE RECTANGULAR CONNECTOR catalog PDF 1475.3KB - download

この製品に関するお問い合わせはこちら